YZC400WE


 

Structure Characteristics

Structure

Item

Standard Value

Inner Conductor

Material

Silver Plated Copper

Construction(mm)

1/0.93

Nom.Dia(mm)

0.93

Insulation

Material

Solid-PTFE

Nom.Dia(mm)

3.00

Inner shield

Material

Silver Plated Copper Strip

Nom.Dia(mm)

3.20

Interlayer

Material

LD-PTFE

Nom.Dia(mm)

3.50

Outer shield

Material

Silver Plated Copper Wire

Nom.Dia(mm)

3.85

Jacket

Material

 Blue TPU

Nom.Dia(mm)

5.00

 

Electrical performance parameters

Item

Standard Value

Attenuation(@25℃&Sea Level) and Power handing@(@40℃&Sea Level)

Impedance (Ohm)

50

(MHz)
Frequency

(dB/100m)
Attenuation

(W)
Power handing

Capacitance(pF/m)

94

500

25.88

772

1000

37.57

532

Velocity of Propagation

70%

2000

55.09

363

4000

81.82

244

Max Operating Frequency(GHz)

34

6000

103.89

192

8000

123.53

162

Screening Effectiveness(dB)

>90

10000

141.64

141

12400

161.94

123

Dielectric Withstanding Voltage(V@DC)

1500

16000

190.34

105

18000

205.32

97

Phase Change VS Bending(°/GHz)

±0.3

26500

264.68

75

K1

1.082677

Phase Change VS Temperature@(-45~+85)℃

N/A

K2

0.003337

IL=K1*√FMhz+K2*FMHz

 

Mechanical and environmental performance

Mechaical &Environmental Characteristics

Replaceable Type

Min Bending Radius (Static)

20.0mm

 

 

Min Bending Radius (Dynamic)

40.0mm

 

 

Weight

0.041kg/m

 

 

Operating Temperature(℃)

 -55~85

 

 

 

Leave us a message