YZG047


 

Structure Characteristics

Structure

Item

Standard Value

Inner Conductor

Material

Silver Plated Copper

Construction(mm)

1/0.29

Nom.Dia(mm)

0.29

Insulation

Material

Solid-PTFE

Nom.Dia(mm)

0.95

Inner shield

Material

Silver Plated Copper Strip

Nom.Dia(mm)

1.10

Interlayer

Material

High temperature aluminium foil

Nom.Dia(mm)

1.23

Outer shield

Material

Alloy wire

Nom.Dia(mm)

1.43

Jacket

Material

 Green FEP

Nom.Dia(mm)

1.80

 

Electrical performance parameters

Item

Standard Value

Attenuation(@25℃&Sea Level) and Power handing@(@40℃&Sea Level)

Impedance (Ohm)

50

(MHz)
Frequency

(dB/m)
Attenuation

(W)
Power handing

Capacitance(pF/m)

94

500

0.81

100

1000

1.15

70

Velocity of Propagation

70%

3000

2.02

40

6000

2.87

28

Max Operating Frequency(GHz)

100

10000

3.74

22

16000

4.77

17

Screening Effectiveness(dB)

>90

18000

5.07

16

26500

6.21

13

Dielectric Withstanding Voltage(V@DC)

500

40000

7.71

11

67000

10.17

8

Phase Change VS Bending(°/GHz)

±0.3

100000

12.65

6

K1

0.03613110

Phase Change VS Temperature@(-45~+85)℃

N/A

K2

0.00001221

IL=K1*√FMhz+K2*FMHz

 

Mechanical and environmental performance

Mechaical &Environmental Characteristics

Replaceable Type

Min Bending Radius (Static)

20.0mm

HUBER+SUHNER

Minibend-047

Min Bending Radius (Dynamic)

40.0mm

 

 

Weight

0.047kg/m

 

 

Operating Temperature(℃)

 -55~125

 

 

 

Leave us a message

Our staff will contact you within 24 hours (working days); if you need other services, please call the contact number:15861607018