YZG047
Structure Characteristics
Structure |
Item |
Standard Value |
Inner Conductor |
Material |
Silver Plated Copper |
Construction(mm) |
1/0.29 |
|
Nom.Dia(mm) |
0.29 |
|
Insulation |
Material |
Solid-PTFE |
Nom.Dia(mm) |
0.95 |
|
Inner shield |
Material |
Silver Plated Copper Strip |
Nom.Dia(mm) |
1.10 |
|
Interlayer |
Material |
High temperature aluminium foil |
Nom.Dia(mm) |
1.23 |
|
Outer shield |
Material |
Alloy wire |
Nom.Dia(mm) |
1.43 |
|
Jacket |
Material |
Green FEP |
Nom.Dia(mm) |
1.80 |
Electrical performance parameters
Item |
Standard Value |
Attenuation(@25℃&Sea Level) and Power handing@(@40℃&Sea Level) |
||
Impedance (Ohm) |
50 |
(MHz) |
(dB/m) |
(W) |
Capacitance(pF/m) |
94 |
500 |
0.81 |
100 |
1000 |
1.15 |
70 |
||
Velocity of Propagation |
70% |
3000 |
2.02 |
40 |
6000 |
2.87 |
28 |
||
Max Operating Frequency(GHz) |
100 |
10000 |
3.74 |
22 |
16000 |
4.77 |
17 |
||
Screening Effectiveness(dB) |
>90 |
18000 |
5.07 |
16 |
26500 |
6.21 |
13 |
||
Dielectric Withstanding Voltage(V@DC) |
500 |
40000 |
7.71 |
11 |
67000 |
10.17 |
8 |
||
Phase Change VS Bending(°/GHz) |
±0.3 |
100000 |
12.65 |
6 |
K1 |
0.03613110 |
|||
Phase Change VS Temperature@(-45~+85)℃ |
N/A |
K2 |
0.00001221 |
|
IL=K1*√FMhz+K2*FMHz |
Mechanical and environmental performance
Mechaical &Environmental Characteristics |
Replaceable Type |
||
Min Bending Radius (Static) |
20.0mm |
HUBER+SUHNER |
Minibend-047 |
Min Bending Radius (Dynamic) |
40.0mm |
|
|
Weight |
0.047kg/m |
|
|
Operating Temperature(℃) |
-55~125 |
|
|
Leave us a message