YZK360


 

Structure Characteristics

Structure

Item

Standard Value

Inner Conductor

Material

Silver Plated Copper

Construction(mm)

1/0.93

Nom.Dia(mm)

0.93

Insulation

Material

ZF402

Nom.Dia(mm)

2.55

Inner shield

Material

Silver Plated Copper Strip

Nom.Dia(mm)

2.72

Interlayer

Material

High temperature aluminium foil

Nom.Dia(mm)

2.85

Outer shield

Material

Silver Plated Copper Wire

Nom.Dia(mm)

3.15

Jacket

Material

Blue FEP

Nom.Dia(mm)

3.60

 

Electrical performance parameters

Item

Standard Value

Attenuation(@25℃&Sea Level) and Power handing@(@40℃&Sea Level)

Impedance (Ohm)

50

(MHz)
Frequency

(dB/100m)
Attenuation

(W)
Power handing

Capacitance(pF/m)

80

500

29.09

711

100

12.79

1617

Velocity of Propagation

82%

3000

74.37

278

6000

108.25

191

Max Operating Frequency(GHz)

40

8000

126.87

163

9000

135.47

153

Screening Effectiveness(dB)

>100

10000

143.69

144

12000

159.24

130

Dielectric Withstanding Voltage(V@DC)

2000

18000

200.81

103

26500

251.81

82

Phase Change VS Bending(°/GHz)

±0.3

40000

322.39

64

K1

1.261948

Phase Change VS Temperature@(-45~+85)℃

≤450 PPM

K2

0.00175

IL=K1*√FMhz+K2*FMHz

 

Mechanical and environmental performance

Mechaical &Environmental Characteristics

(Phase change VS Temperature)

Min Bending Radius (Static)

18.0mm

Min Bending Radius (Dynamic)

36.0mm

Weight

0.033kg/m

Operating Temperature(℃)

 -55~125

 

Leave us a message